BasilarM_DRNLT: Test version of DRNL model
File
name
|
MoBM0DRNL.[ch]
|
|
|
Description
|
Test
module for the DRNL Composite filter, used to model the non-linear response of
the Basilar Membrane. This module provides the user with comprehensive control
of the model's parameters.
|
|
|
Example
parameter file format
|
4 Total order for the gamma tone filters - BM model.
single Frequency mode.
8000.0 Centre frequency of gamma-tone filter for basilar membrane.
user Band width (3 dB down) mode for filters.
1343 Bandwidth (Hz).
1.0 Narrow filter broadening coefficient.
6.0 Threshold above which compression takes place (dB SPL).
0.58 Compression ratio.
5453 Wide filter Centre Frequency (Hz).
1823 Wide filter band width (Hz).
-25.95 Wide filter attenuation (dB SPL).
2.5 Narrow filter low-pass cut-off scale.
|
|
|
Test
program directory
|
Tests/Models/Basilar_M,
Tests/SSPrograms
|
This module has the standard Generic Module Routines (see Basic Module Routines
used in Generic Programming, page 52).
Syntax
|
BOOLN _BasilarM_DRNL_Test(EarObjectPtr data);
|
|
|
Returns
|
TRUE
if the process is successful, otherwise it returns FALSE.
|
Syntax
|
CFListPtr GetCFList_BasilarM_DRNL_Test(void);
|
|
|
Special
Values
|
(The
CFList structure is controlled by the UtCFList module routinessee 0
Using the Basilar Membrane Filter Modules.
|
|
|
Returns
|
Pointer
to the modules CFList structure.
|
Syntax
|
BOOLN SetBandwidths_BasilarM_DRNL_Test(char
*theBandwidthMode, double *theBandWidths);
|
|
|
Special
Values
|
(The
bandwidth mode is controlled by the UtBandwidth module routines).
|
|
|
Returns
|
TRUE
if the function is successful, otherwise it returns FALSE.
|
Syntax
|
BOOLN SetCFList_BasilarM_DRNL_Test(CFListPtr
*theCFList);
|
|
|
Special
Values
|
(The
CFList structure is controlled by the UtCFList module routinessee 0
Using the Basilar Membrane Filter Modules.
|
|
|
Returns
|
TRUE
if the function is successful, otherwise it returns FALSE.
|
Syntax
|
BOOLN SetCompressionExponent_BasilarM(double
theCompressionExponent);
|
|
|
Returns
|
TRUE
if the function is successful, otherwise it returns FALSE.
|
Syntax
|
BOOLN SetCompressionThreshold_BasilarM_DRNL_Test(double
theCompressionThreshold);
|
|
|
Returns
|
TRUE
if the function is successful, otherwise it returns FALSE.
|
Syntax
|
BOOLN SetNarrowBroadeningCoeff_BasilarM_DRNL_Test(double
theNarrowBroadeningCoeff);
|
|
|
Returns
|
TRUE
if the function is successful, otherwise it returns FALSE.
|
Syntax
|
BOOLN SetNarrowFLPCutOffScale_BasilarM_DRNL_Test(double
theNarrowFLPCutOffScale);
|
|
|
Returns
|
TRUE
if the function is successful, otherwise it returns FALSE.
|
Syntax
|
BOOLN SetOrder_BasilarM_DRNL_Test(double
theOrder);
|
|
|
Returns
|
TRUE
if the function is successful, otherwise it returns FALSE.
|
Syntax
|
BOOLN SetPars_BasilarM_DRNL_Test(int theOrder,
double theNarrowBroadeningCoeff, double theCompressionThreshold,
double theCompressionExponent, double wideFCentreFreq, double
wideFWidth, double wideAttenuation, double
narrowFLPCutOffScale, CFListPtr theCFs);
|
|
|
Returns
|
TRUE
if the function is successful, otherwise it returns FALSE.
|
Syntax
|
BOOLN SetWideAttenuation_BasilarM_DRNL_Test(double
theWideAttenuation);
|
|
|
Returns
|
TRUE
if the function is successful, otherwise it returns FALSE.
|
Syntax
|
BOOLN SetWideFWidth_BasilarM_DRNL_Test(double
theWideFWidth);
|
|
|
Returns
|
TRUE
if the function is successful, otherwise it returns FALSE.
|
Syntax
|
BOOLN SetWideFCentreFreq_BasilarM_DRNL_Test(double
theWideFCentreFreq);
|
|
|
Returns
|
TRUE
if the function is successful, otherwise it returns FALSE.
|
#
# Main Parameter file
#
output.dat Name of output file.
# Module specifications.
#Par. file Name Description
#--------- ----- -------------
ParFiles/St/PTone5.par PureTone Stimulus generation.
SimSpecs/BM/DRNLTInt.sim Utility_SimulationSpec Simulation spec.
# Miscellaneous parameters
100.0 Lowest frequency for pure tone probe stimulus (Hz).
1000.0 Highest frequency for pure tone probe stimulus (Hz).
40 No. of frequencies within range (logarithmic).
2.5e-3 Ramp up rise time for signal (s).
Figure [81] Filter function at CF = 300 Hz for the test version of the DRNL
BM model.
#
# Main Parameter file
#
output.dat Name of output file.
#
# Module specifications.
#
#Par. file Name Description
#--------- ----- -------------
ParFiles/St/PTone5.par PureTone Stimulus generation.
SimSpecs/BM/DRNLTInt.sim Utility_SimulationSpec Simulation spec.
# Miscellaneous parameters
100.0 Lowest test centre frequency (Hz).
1000.0 Highest test centre frequency (Hz).
40 The no. of channels within the frequency range.
5000.0 Minimum frequency for sampling interval setting (Hz).
2.5e-3 Ramp up rise time for signal (s).
0 Conversion mode (0 = unity mode, 1 = (mm/s?), 2 = (nm?).
0 Target threshold (?).
0.1 Target accuracy (?).
0.009 Conversion scale factor (? - not used with unity mode).
Figure [82] Tuning Curve at CF = 300 Hz for the test version of the DRNL BM
model.
#
# Main Parameter file
#
output.dat Name of output file.
#
# Module specifications.
#
#Par. file Name Description
#--------- ----- -------------
PTone4.par PureTone Stimulus generation paradigm.
GPigChinPE.par PreEmphasis_BandPass Outer-/middler-ear filter model.
DRNLT18k.par BasilarM_DRNL_Test Basilar membrane filter.
#
# Miscellaneous parameters
#
10 No. of intensity level readings calculated.
0 Initial intensity value (dB SPL).
10.0 Incremental change in intensity.
2.5e-3 Ramp up rise time for signal (s).
See figure [59] on page Error! Bookmark not defined.. Note that
the input-output function for this filter has a "compression elbow" at ~30 dB
SPL..
#
# Main Parameter file
#
output.dat Name of output file.
#
# Module specifications.
#
#Par. file Name Description
#--------- ----- -------------
PTone4.par PureTone Stimulus generation paradigm.
GPigChinPE.par PreEmphasis_Bandpass Outer-/middler-ear filter model.
DRNLT18k.par BasilarM_DRNL_Test Basilar membrane filter.
#
# Miscellaneous parameters
#
10 No. of intensity level readings calculated.
0 Initial intensity value (dB SPL).
10.0 Incremental change in intensity.
20000.0 Initial stimulus frequency (Hz).
1000.0 Final stimulus frequency (Hz).
2000.0 Stimulus frequency decrement (Hz).
2.5e-3 Ramp up rise time for signal (s).
Figure [83] The input-output functions for the test version of the DRNL BM
model. Both on and off CF functions are shown. Note that the off-CF
input-output functions show compression at higher intensities.
#
# Main Parameter file
#
output.dat Name of output file.
#
# Module specifications.
#
#Par. file Name Description
#--------- ----- -------------
PTone4.par PureTone Stimulus generation paradigm.
DRNLT18k.par BasilarM_DRNL_Test Basilar membrane filter.
#
# Miscellaneous parameters
#
100.0 Lowest frequency for pure tone probe stimulus (Hz).
10000.0 Highest frequency for pure tone probe stimulus (Hz).
10 No. of frequencies within range (logarithmic).
2.5e-3 Ramp up rise time for signal (s).