Carney1k.par 4 Order for the gamma tone filters - BM model. single Centre frequency mode for filter. 1000.0 Initial centre frequency of gamma-tone filter bank. 1100 Cut-off frequency for OHC low-pass filter, Fc (Hz). 5000 Operating point of OHC (feedback) non-linearity, P_Dfb (Pa). 0.462 Asymmetrical bias for OHC non-linearity, P0 (rad). 10.0 Maximum depolarising hair cell voltage, Vmax (V). CookeAMP1k.par single Centre frequency mode for filter. 1000.0 Initial centre frequency of gamma-tone filter bank. ERB Band width (3 dB down) mode for filters. 1.019 ERB Bandwidth correction 4th order. POW Output option (BM, POW, AMP). CookeBM1k.par single Centre frequency mode for filter. 1000.0 Initial centre frequency of gamma-tone filter bank. ERB Band width (3 dB down) mode for filters. 1.019 ERB Bandwidth correction 4th order. BM Output option (BM, POW, AMP). DRNL18k.par 4 Total order for the gamma tone filters - BM model. single Frequency mode. 18000 Centre frequency of gamma-tone filter for basilar membrane. Nonlinear Band width (3 dB down) mode for filters. 1.0 Narrow filter broadening coefficient. 29.5 Threshold above which compression takes place (dB SPL). 0.63 Compression ratio. 1.0 Wide filter broadening coefficient. 2.5 Narrow filter low-pass cut-off scale. DRNL1k.par 4 Total order for the gamma tone filters - BM model. single Frequency mode. 1000 Centre frequency of gamma-tone filter for basilar membrane. Nonlinear Band width (3 dB down) mode for filters. 1.0 Narrow filter broadening coefficient. 20.0 Threshold above which compression takes place (dB SPL). 0.66 Compression ratio. 1.0 Wide filter broadening coefficient. 2.5 Narrow filter low-pass cut-off scale. DRNLT300.par 4 Total order for the gamma tone filters - BM model. single Frequency mode. 171 Centre frequency of gamma-tone filter for BM. user Band width (3 dB down) mode for filters. 188 Bandwidth (Hz). 1.0 Narrow filter broadening coefficient. 82.0 Threshold above which compression takes place (dB SPL). 0.65 Compression ratio. 482 Wide filter Centre Frequency (Hz). 207 Wide filter band width (Hz). -19 Wide filter attenuation (dB SPL). 2.5 Narrow filter low-pass cut-off scale. DRNLT8k.par 4 Total order for the gamma tone filters - BM model. single Frequency mode. 8000.0 Centre frequency of gamma-tone filter for basilar membrane. user Band width (3 dB down) mode for filters. 1343 Bandwidth (Hz). 1.0 Narrow filter broadening coefficient. 20.0 Threshold above which compression takes place (dB SPL). 0.63 Compression ratio. 5453 Wide filter Centre Frequency (Hz). 1823 Wide filter band width (Hz). -25.95 Wide filter attenuation (dB SPL). 2.5 Narrow filter low-pass cut-off scale. GammaT1k.par 4 Order for the gamma tone filters - basilar membrane model. single Centre frequency mode for filter. 1000.0 Initial centre frequency of gamma-tone filter bank. ERB Band width (3 dB down) mode for filters.